Blog / manifold

Positioning the underfloor heating manifold

by UFH1
Positioning the underfloor heating (UFH) manifold is an important aspect of your UFH system. It is often thought that it needs to be near the boiler/cylinder/heat pump. It is in fact better to be in the room where the UFH system is to be fitted or very close by if it’s a single room (single zone) system or somewhere central for multi-room (multi-zone) system.
Continue Reading

I have a one room set-up, which kit should I go for?

by UFH1
Firstly you need to determine the size of the area to be heated and what pipe centres you need to install at – this will be determined by the heat source, the room type and possibly the floor covering. In Conservatories, wet rooms and areas with large glazed parts we recommend installing the pipes at 100mm spacing to compensate for the higher heat loss. If using an air or ground source heat pump, the pipes should be at 100mm regardless of the room type. A boiler based system in a standard solid construction room would usually have pipe installed at 200mm spacing.
Continue Reading

Product Warranties

by UFH1
Our products are manufactured in Europe and meet the highest possible accreditations in underfloor heating. We offer industry leading warranties based on the following: 50 year pipe warranty 10 year manifold warranty 2 year pump warranty
Continue Reading
Free CAD
Service
Full Installation
Service
Industry Leading
Warranty
Best UK
Trade Rates
We Will Beat
Any Quote