How Long Does Underfloor Heating Take to Warm Up? (And Should You Leave It On?)

by UFH1

How long does underfloor heating take to warm up? An electric mat or a low profile wet system will usually warm a room in under an hour. A wet system laid in screed is slower, typically taking two to three hours, and longer if the floor has gone completely cold.

That last point explains why the figures you'll see quoted vary so much. Warming a floor from cold takes far longer than bringing it back up from a few degrees lower, and how you run your heating makes a big difference to how quickly it responds. Below, we cover typical times for each type of floor, how to run each system, and what to check if yours seems slower than it should be.

In This Guide

How Long Does Underfloor Heating Take to Heat Up? Times by Floor Type

These are typical times to warm a room from cold. Your own system may be quicker or slower depending on insulation, the floor finish and the system's heat output.

System Typical build-up Warm-up from cold Why
Electric mat on insulation boards Mat under tiles, on insulation Around 30 to 60 minutes Thin layers, and the insulation sends heat up into the room
Electric mat on bare concrete Mat under tiles, no insulation Noticeably slower Some of the heat goes down into the slab first
Low profile or overfloor wet system Pipes in thin boards (around 18 to 25mm) Around 30 minutes to an hour Very little material between the pipes and the floor surface
Wet pipes in screed Pipes in screed, often 65mm or more Around 2 to 3 hours, longer from fully cold The screed has to warm up before the room does

Why Some Floors Take Longer to Warm Up

The main reason as to why some floors take longer to heat up is thermal mass, which is how much material sits between the heat source and the room. A screed floor is a thick, heavy slab, and all of it has to warm up before the surface feels warm. The trade-off is that it then holds that heat for hours after the heating goes off. A thin electric mat or low profile system is the opposite: quick to warm up, and quick to cool down.

Three other things affect warm-up time:

  • Insulation underneath: without it, heat escapes downwards into the subfloor instead of rising into the room. Insulation boards such as our XPS insulation make a big difference to how quickly a floor responds.
  • The floor finish: tiles and stone pass heat through quickly. Wood, laminate and especially thick carpet with heavy underlay slow it down. Our guide to flooring that works with underfloor heating covers each type.
  • Heat output: a higher-output electric mat, or a wet system running at a higher water temperature, warms the floor faster.

Should You Leave Underfloor Heating On All the Time?

It depends on the type of system. As a general rule, the slower your floor is to warm up, the less sense it makes to switch it off completely:

System How to run it Why
Wet system in screed Leave it on, with a lower setback temperature overnight and when you're out Avoids reheating a cold slab from scratch, which takes hours
Wet system on a heat pump Leave it on for long, steady periods, with small setbacks Heat pumps work most efficiently running gently for longer
Low profile wet system Timed heating periods, starting 30 to 60 minutes before you need the room Responds quickly enough to switch on and off
Electric mat Timer or programmable thermostat, on shortly before you need the room Warms up fast, and you only pay for the hours it's on

A setback temperature is a lower temperature the thermostat holds when you don't need full heat, typically a few degrees below your normal setting. The Energy Saving Trust recommends this approach for heat pumps rather than turning the heating off and on.

Leaving a screeded system on with a setback isn't free, but it avoids the long, energy-hungry climb from a cold floor. A programmable or smart thermostat makes setbacks easy to schedule; our underfloor heating controls include both, and our post on smart phone control of your underfloor heating explains how app control works.

Is Your Underfloor Heating Slower Than It Should Be?

If your floor takes much longer to warm up than the times above, run through these questions before calling anyone out:

  • Is it warming up from cold every day? If the heating goes fully off overnight, a screed floor has to start from scratch each morning. Try a setback temperature instead and see whether the morning warm-up improves.
  • Is the water temperature too low? A wet system running at a low flow temperature will take longer to warm the floor. This is common with heat pumps, which are often set up to run at low temperatures for efficiency. Your installer can check whether the setting suits your floor.
  • Is there insulation under the system? On an uninsulated floor, a lot of the heat goes into the ground. This is hard to fix after the floor is laid, but it explains why some older or retrofit systems are slow.
  • Is the floor covering too thick? Heavy rugs, thick carpet and dense underlay can slow the heat down a lot. Check our guide to underfloor heating with carpet for what to look for.
  • Are all the zones opening? On a wet system, each zone has an actuator on the manifold that opens when its thermostat calls for heat. If one has failed, that room won't warm up at all. Our guide to controlling the room temperature with underfloor heating explains how thermostats and actuators work together.
  • Has the system been balanced? If some rooms warm up much faster than others, the flow through each circuit may need adjusting at the manifold.
  • Is it a new screed? A screed that's still drying out holds moisture, which can make the first few weeks of normal use feel sluggish.

If none of these explains it, or you've noticed cold patches, our guide to troubleshooting common underfloor heating problems covers the faults worth getting looked at.

Frequently Asked Questions

How long does electric underfloor heating take to warm up?

An electric mat on insulation boards under tiles usually warms a room in around 30 to 60 minutes. On bare concrete, or under thicker floor coverings, it will take longer. Setting it on a timer to come on shortly before you need the room is an efficient way to run it.

How many hours a day should underfloor heating be on?

There's no single answer, because it depends on the system. A screeded wet system works well left on, with a lower setback temperature overnight. An electric mat or low profile system only needs to be on for the hours you're using the room, plus 30 to 60 minutes to warm up.

How can I tell if my underfloor heating is working?

The floor should feel gently warm to the touch, not hot, once the system has had time to warm up. On a wet system, the manifold pipes for a zone that's calling for heat should feel warm. If one room stays cold while others warm up, check its thermostat and actuator.

Does underfloor heating take longer to cool down?

Yes, particularly screeded systems. The same thermal mass that makes them slow to warm up keeps them releasing heat for hours after the heating switches off. Electric mats and low profile systems cool down much faster, which makes them easier to control in rooms you use for short periods.

Want a system that responds the way you live? If you're planning a new installation, or your current system has never felt right, send us your plans for a free, no obligation specification and quote.